The first cold mornings of the year are when a lot of Arizona homeowners find out what their heat pump actually does in winter. Steam coming off the outdoor unit, a loud whoosh, air that feels warm but not hot. Most of it is normal. Some of it isn't. Here's how to tell the difference before you call.
On cool, damp mornings, frost can build up on the outdoor coil. The system clears it by briefly running in reverse. You may see steam rising from the unit, hear the fan stop and then a whoosh as the valve switches back. That cycle usually lasts a few minutes and is exactly what the system is supposed to do.
Why It Matters: A heat pump that never defrosts can ice over and lose most of its heating ability, so a defrost cycle is a good sign, not a bad one.
A gas furnace blows very hot air in short bursts. A heat pump delivers air that feels warm rather than hot, and it runs longer, steadier cycles to get the house to temperature. If your vents feel warm and the house is holding the set point, the system is working.
Pro Tip: Hold your hand at a supply vent, not near a window or exterior wall. Drafty spots can make a working system feel weaker than it is.
Many heat pumps have electric heat strips as backup. "Aux" heat turns on by itself when the heat pump needs help, like during defrost or a big temperature jump. "Emergency" heat is a setting you choose, and it runs the heat strips alone. Heat strips are far more expensive to run than the heat pump itself.
What to Do: Leave the thermostat on HEAT. Only use EM HEAT if the outdoor unit has stopped working and you're waiting on a repair.
Backup heat strips are one of the biggest electrical loads in the house. If a breaker trips the first time the heat runs each season, or every time aux heat comes on, the system is telling you something. It could be a failing heat strip or a problem in the air handler, which is our side. It could also be a loose connection, a worn breaker or a circuit that was never sized right, which is electrical work.
What to Do: Don't keep resetting it. Call us to check the equipment first. If the HVAC side checks out, our sister company The Wire Guy Electric can find out why a breaker keeps tripping and fix the cause instead of the symptom.
A light layer of frost that clears after a defrost cycle is normal. A thick block of ice that stays on the coil all morning is not. It can point to low refrigerant, a failed defrost control, or airflow problems.
Quick Fix: Check that the air filter is clean and that nothing is blocking the outdoor unit. If the ice is still there after an hour, turn the system to EM HEAT and call for service.
Arizona winters are short, but a heat pump that isn't working right can still run up a bill or leave you cold on the mornings you need it most. At The Cooling Guy HVAC, we'll tell you honestly whether you're seeing normal winter behavior or a real problem.